AS 1562.1:2018

Original price was: $98.00.Current price is: $49.00.

Design and installation of metal roof and wall cladding, Part 1: Metal

File Format: PDF

Category:
This Standard sets out requirements for the design and installation of self-supporting metal roof and wall cladding, subjected to out-of-plane external actions and in-plane thermally induced actions, permanent actions on walls and steep roofs and frictional drag of wind and snow actions.

Header

About this publication

Preface

1 Scope and general

1.1 Scope

1.2 Normative references

1.3 Definitions

2 Materials

2.1 Sheets, rolled sections and extrusions used for the manufacture of cladding and accessories

2.1.1 Aluminium

2.1.2 Copper

2.1.3 Steel

2.1.4 Stainless steel

2.1.5 Prepainted

2.1.6 Other metals

2.2 Sheet fastenings

2.2.1 General

2.2.2 Aluminium

2.2.3 Copper and copper alloys

2.2.4 Steel

2.2.5 Stainless steel

2.2.6 Rivets

3 Design

3.1 Scope

3.2 Loading

3.2.1 General

3.2.2 Imposed actions

3.2.3 Wind actions

3.2.4 Snow and ice action

3.2.5 Lateral restraint

3.2.6 Thermally induced movement or loadings

3.3 Roof drainage

3.3.1 General

3.3.2 Roof pitch

3.3.3 Rainwater goods

3.4 Protection against corrosion

3.4.1 General

3.4.2 Direct contact

3.4.3 Run-off

3.5 Design documentation

4 Installation

4.1 Overview

4.1.1 General

4.1.2 Loading during construction

4.2 Supporting members

4.2.1 Spacing of supporting members

4.2.2 Supports at hips and valleys

4.2.3 Tolerance in position of supporting members

4.3 Laying the sheeting

4.4 Fastening

4.4.1 General

4.4.2 Pierced-fastened cladding

4.4.3 Concealed-fastened cladding

4.5 Cladding laps

4.6 Protection of cladding during installation

4.7 Projections through the cladding

4.8 Flashings

4.8.1 General

4.8.2 Minimum thickness

4.8.3 Fastening

5 Testing

5.1 General

5.2 Test specimen

5.3 Derivation of design values

5.3.1 Serviceability test pressure

5.3.2 Ultimate test pressure

5.3.3 Serviceability design pressure

5.3.4 Ultimate design pressure

5.4 Resistance to concentrated loads

5.4.1 General

5.4.2 Serviceability test

5.4.3 Strength test

5.5 Resistance to wind pressures for non-cyclone regions

5.5.1 Serviceability test

5.5.2 Strength test

5.6 Resistance to wind pressures for cyclone regions

5.6.1 General

5.6.2 Serviceability test

5.6.3 Strength test

Appendix A

A1 Causes of condensation

A2 Roof condensation

A3 Problems caused by condensation

A4 Preventing the effects of condensation

Appendix B

B1 Water Penetration

B2 Minimizing water penetration

Appendix C

Appendix D

Appendix E

Bibliography